Usage
Model LFX shunt rotor steam flow meter (hereinafter referred to flow meter), is a kind of flow meter that measures the steam or superheated steam when flowing through pipelines, it can show total mass flow of steam or transient value in the scene or in the Far East . Intelligent temperature can be measured superheated steam flow meter With , , orifice of cutting expenditure, cutting expenditure by the replacement of the orifice to flow, the features of this kind of flow meter contain: wide measuring range, high precision, TING Long life, convenient in operating and maintaining; It can be widely used in measuring the steam in the industry of petroleum, chemicals and light industrial sectors etc.
Structure and working principle
Flowmeter, with its working principle of differential pressure , is mainly made up of cutting expenditure, damper and indicator, measured medium Flowed into the flow meter to cut two parts of expenditure, one part of the expenditure flowed through the competent Road orifice, and the other part diverted into of the nozzle, and Jet to the impeller, which form torque to Impeller, and driven rotor shaft rotation; in the lower part of the rotor shaft, blade damper is installed in the damping Room which full-filled with damping, rotating impeller is restricted, which caused the impeller speed is much slower than the speed of the jet steam, so impeller can effectively absorb the steam jet speed, and make the speed of rotation and torque and damping caused by steam injection corresponding, and formed a set of relations. Speed and impeller Proportionally flow.
| Forms |
LFXһ25 |
LFX-50 |
LFXһ80 |
LFXһ100 |
| The diameter |
25 |
50 |
80 |
1 00 |
|