Technical parameters
Accuracy Rating: 0.2
Show: 8 LED Display
Input: Analog and pulse volume
Cumulative flows: automatic storage
Display window: single-window, dual-window
Dimensions: 160 80 horizontal panels
Main Features
Showing intuitive, high-performance
XS Series Flow Totalizer-type flow sensors and a transmitter with the completion of the instantaneous flow measurement, transformation, transmission and control, at the same time the cumulative calculation.
error is less than 0.2% F. S, and have adjusted, digital filtering features to help reduce the sensor, the transmitter of error, effectively improve the system of measurement, control accuracy
applicable to the current, voltage, pulse output of the flow sensor or transducer
2alarm output for instantaneous flow, the lower limit of the police or the cumulative output of Preferences
transmission output can be measured, since the transformation was instantaneous flow value as a standard current, voltage output form for the use of other equipment
cumulative output of pulses
instantaneous flow into by the hour or the unit of measure can choose
full transparency, high-speed, efficient communications network interface, computer and instruments to achieve the complete data transfer between and control. Exclusive right to transfer the functions of the computer can directly control the instrument alarm transmission output and exports. Read the first measurements of time is less than 10ms
To provide software testing, configuration software and application software technical support
have the hardware clock with a print interface and printing unit, and manual, time, alarm printing function, if the matching Smart printing unit, can achieve more than one instrument to share one printer
size and shape a variety of forms panel
for non-linear signals, the instrument can be used in paragraph 8 of broken line function
blackout record can be recorded total blackout, power outage and the last eight times the number of blackouts and power of real-time time. Through panels out of view
Model specifications
12345678910111213
XSJ / - T B A S V
1: Size appearance
A: Cross-160 80 125 or vertical 80 160 125 (W H L)
B: 96 96 112 (W H L)
C: 96 48 112 (W H L) can only horizontal single significant
2: panel form H: Cross-S: vertical F: square
3: Show:
1: 8-LED display, and the cumulative value of instantaneous switching show
2: 8 +4-LED dual-display, and the cumulative value of the instantaneous value at the same time show
4: input signal
I: DC
V: DC
K: pulse input
5: alarm at the number of
T0: No alarm
T1-T2: 1-2 point alarm
6: for power,
B0: No, for power
B1: for 24V DC,
B2: for 12V DC,
B3: Other
7: transmission output
A0: No output
A1: current output (4 - 20) mA, (0 - 10) mA or (0 - 20) mA
A2: voltage output (0 - 5) V, (1 - 5) V
A3: voltage output (0 - 10) V
A4: Other output
8: Communication Interface
S0: No communication interface
S1: RS 232 interface
S2: RS 485 interface
S3: RS 422 interface
9: Power Meter
V0: 220V AC
V1: 24V DC
V2: 12V DC
10: printing function: P said that with printing, can be omitted without (limited appearance for the A, B instrument)
11: blackouts record: D blackout that brought the record, can be omitted without (limited to dual-display meters)
12: Cumulative output of pulse: O that have accumulated output of pulse, can not omit
13: N said that non-standard features. Instrument function of a certain part of the requested change orders
|