Flowmeter Series
  • Steam flow meter
  • LUGB Vortex Flowmeter
  • LWGY liquid turbine flowmeter
  • LWGQ gas turbine flowmeter
  • LWGI insertion flowmeter
  • RXLDB series of electromagnetic flowmeter
  • LZ metal rotor Flowmeter
  • LZB glass rotor Flowmeter
  • LC Series oval gear flow meter
  • LFX rotor steam-Meter
  • Flow Totalizer & Quantitative control instrument
  • XSJ-Flow Totalizer
  • Ration controller meter of XSJDL series
  • Temperature, pressure equalization calculator of XSJB series
  • XS-Flow Totalizer
  • WP-LK80 Flow Totalizer
  •  
    Enterprise mission:
    Self developing, repay the world
    Company tenet
    Quality first, reality makes the business.
    Company spirit:
    Simple, concordant human relations
    Thanksgiving people loyal to the criteria
    Competition progressive attitude towards life
    Together the team
    Corporate motto:
    People-oriented, quality-win, Leading to services, And there is, out of a new, The best from XUNYI
    Metal rotor Flowmeter of LZ series

    LZ series of metal tube float flowmeter apply to small flow of the medium low Reynolds number flow measurement, the flow meter on the instructions of a function or the Far East, Far EasTone output to a standard 4 ~ 20mA signal. Limit can be configured

    Digital switches, control the police. The instrument has a rational structure, the use of easy maintenance, pressure loss of small, reliable, surveying a wide range and so on.

    LZ series of metal tube float a flow meter showed that the spot-and smart-Far EasTone, with indicators show an instant / cumulative flow of liquid crystal display, on the threshold alarm output, and the cumulative pulse output, batch control, the standard second-line system 4-20 mA Current output, and other means for users to provide a very broad choice, and the instruments used Motorola's advanced micro-processing chip and the industrialization of high-quality components to ensure that the flow meter in various places of the excellent performance. Over the years, the metal tube float Flowmeter excellent performance and reliability, and better cost performance, has been widely petrochemicals, steel, electricity, metallurgy, light industry, foodstuffs, pharmaceuticals, water treatment and other industries Favor.

    principle:

    LZ series of metal tube float flowmeter made by the two main components: measuring indicator and the CPD. Including the measurement of or Cone of the orifice, the director, actuators, float and other components, including magnetic indicator follow-up system, the guide, dial, wait until the line components.

    Tested medium flows through bottom-up measurements of the float from top to bottom-up form of a differential pressure, when the float of the Baptist suffered increase in the flow of fluid in the float weight, the float will rise, annulus area increases, the Central gap Fluid flow rapidly declining, from top to bottom Float-pressure lowering, role in the rise of the float with the decrease, until the rise of the Baptist and the fluid balance in the float weight, the float will be stable at a certain location, location float to the level that should be Measured the flow of medium size. Float built-in magnet, the float with the media only move up or down, the movement of the magnetic field with the float changes.

    main characteristics:

    Apply to small-calibre medium and low-velocity flow measurement
    Reliable, maintaining a small amount of long life.
    For straight paragraph Yaoqiubugao, wider than the flow of 10:1
    Double-largest liquid crystal display, optional scene instantaneous / cumulative flows, which can carry backlight
    Uniaxial sensitive instructions
    All-metal structure, suitable for high-temperature, high pressure and strong aggressive media

    Can be used in flammable and explosive occasions
    main technical parameters:
    Accuracy Rating: 1.5
    Survey: Water: 25 ~ 100000L / h
    Air: 0.7 ~ 1500m3 / h
    Range ratio: 10:1
    Nominal pressure: DN15, DN25, DN50 for the PN 10MPa
    DN80, DN100 for the PN 6.3MPa
    Ambient temperature: -40 ~ 70
    Tested medium temperature: -40 ~ 200
    200 (high-temperature type)
    Power introduction of mouth: M20 1.5 (Thread)
    Applicable medium viscosity: DN15: <5mPa.s (FZ15.1, FZ15.2, FZ15.3)
    <30 mPa.s (FZ15.4, FZ15.5, FZ15.6, FZ15.7, FZ15.8)
    DN25: <250 mPa.s
    DN50 ~ 100: <300mPa.s
    Flange standards: JB/T82.1-94 (flat flange) JB/T82.2-94 (convex flange)
    Instrument structure
    Flowmeter mainly by the measure and indicator two major components, according to the different connections can be divided into vertical installation and the installation of two levels.
    Measurement is part of
    Basic types: access parts of material 0 Cr19Ni9, applicable to the liquid measurement.
    Anti-corrosion type: PTFE liner, apply to the aggressive media measurement.
    Folder: the need for insulation or cooling medium occasions, the jacket connecting flange DN15, PN1.6.
    Damping type: apply to gas measurement.
    Some indicators
    On the instructions of: used on the instructions of the instantaneous flow.
    Far EasTone type: 4 ~ 20mA output of the DC signal, and Far EasTone function.
    - Alarm: Alarm need for the occasion.
    Selection:

    Model

                 

    Content

    LZ-

                 

    LZ series of metal tube float Flowmeter

     

    R1

               

    Then liquid material 1Cr18Ni9Ti

     

    R2

               

    Then liquid material 0Cr19Ni9

     

    R3

               

    Then liquid material 0Cr18Ni12Mo2Ti

     

    R4

               

    Then liquid material 00Cr17Ni14Mo2(316L)

     

    F

               

    Then liquid materialPTFE

       

    X

             

    Locally-based instruction

       

    Y

             

    + Remote-spot instructions (Intrinsically Safe)

         

    K

           

    Upper and lower limits of the police

         

    K1

           

    Upper and lower limits of the police

         

    W

           

    No alarm

           

    B

         

    Insulation folder

           

    W

         

    Insulation folder

             

    D

       

    Medium temperature : 40 100

             

    G

       

    Medium temperature :200

               

    Z

     

    Damping -

               

    W

     

    Damping -

                 

    S

    The level of installation

                 

    C

    Installation of vertical

    LZ

     
    For example Selection
    LZ-R2YWWDWC for LZ series of metal float flowmeter, and then liquid material for 0 Cr19Ni9, local instructions + Far EasTone (nature of security), no alarm, no insulation jacket, medium temperature range of -40 ~ 100 , without damping Type, vertical installation.
    The calibre flow measurement values corresponding table:

    Calibre

    Calibration medium water L h

    Calibration medium air
    m 3 h

    Stainless Steel Float

    PTFE Float

    Stainless Steel Float

    DN15

    25 600

    25 400

    0.7 16

    DN25

    1000 6000

    600 2500

    3.0 150

    DN50

    6000 25000

    4000 10000

    180 1000

    DN80

    25000 40000

    16000 25000

    1000 1200

    DN100

    100000

    40000

    1800

    Air calibration state T = 20 , P = 0.1013Mpa
    Filters
    If the medium containing solid particles, in the upper reaches of the straight before the installation of the corresponding particle filters to filter out impurities, if the medium of magnetic material containing iron, should be in the purchase of the aircraft at the same time, with my company's magnetic filter to Anti-impact on the accuracy of the instrument and extend the life of instrument. Magnetic filter (see Figure 2), and then liquid material can be 0 Cr19Ni9, 00Cr17 - Ni14Mo2, PTFE and other materials selected.
    Installation requirements
    1. Instrument can be installed in vertical or horizontal pipes, the vertical flow of the media must be a bottom-up. The level of flow meters and the media should be the arrow on the same direction. Instrument upstream equipment 5 DN long straight, the lower reaches of set 250 mm long straight, the set-conditioning flow valve, its location should be in the lower reaches of the instrument straight after paragraph.
    2. Recommend the installation, set up bypass pipeline (see right). Recommend the use of lead-foot hammer and the installation of vertical flow meter testing, to ensure that the flow meter accuracy.
    3. Pipes installed in the flow meter should not be subject to external force, in the appropriate place flowmeter installation of import and export support, the basic flow meter can not be forcing.
    4. PTFE lined installation (PTEE) flowmeter, fastening flange bolts should be especially cautious, only once excessive demands symmetry fastening tight to prevent deformation of PTFE.
    5. In order to avoid shocks measuring fluid within the float, using the instrument to be slow to open the valve, in particular the medium used to measure gas flow, in the lower reaches of the instrument straight after the installation of gas damping device or to the maximum throttle Float to reduce vibration.

     
    Changzhou XunYi Automation Equipment Package Co.,LTD. © 2004-2008 ICP06027658 | flowmeter
    TEL+86-519-882230208831081886577655FAX+86-519-86909383MOB13861082011
    Address: Hu Tang people Road 158,Jiangsu Province,Changzhou City,China
    Link: Flowmeter,  Flowmeters,  Flow Meter,  Flow Meters
    E-mailsale@sensortop.com