Instruction
Get used to the temperature needed, the calculation of flow and volume of the steam-gas of equalization of pressure, saturation steam, common gas.
Temperature, pressure, flow (current, voltage, pulse) input, basic error is better than 0.2%F.S
Cumulation, instantaneous of flow before and after equalization, density, temperature, pressure, are displayable.
Size: 160x80, 96x96
Voltage: 220V AC, 9~30V DC
Basic Equipment:
Duel display, outside transformer as its power supply.
Extended function
Alarm output, 2 points max, configuration is available.
Transformer output or accumulating pulse output.
Communication interface, RS 232 or RS 485
Record without power supply (guard against theft)
Module list
1 size
A: Horizontal: 16080125, hoist high: 80160125WHL
B: 9696112WHL
2 Form of interface
H: Horizontal
S: Hoist high
F: Squareness
3 Alarm points
T0: No alarm
T1~T2: 1-2 alarm points
4 Transformer output
A0No output
A1: Current output 4~20mA0~10mA or0~20mA
A2: Voltage output: 0~5V1~5V
A3: Voltage output 0~10V
A4: Other
5 Outer power supply
B0: No outer power supply
B1: 24V DC outer supplied
B2: 24V DC, 12V DC outer supplied
B3: Other
6 Communication interface
S0: No Communication interface
S1: RS 232
S2RS 485
S3RS 422
7Printing functionP shows it is printable, or it is without printing function.
8Record without power supplyD shows it is available, or it is without such function.
9Instrument power supply
V0220V AC
V124V DC
V212V DC
10Flow input signal
L1Current4mA~20mA DC0mA~10mA DC0mA~20mA DC
L2Voltage1V~5V DC0V~5V DC
L3Pulse
11Temperature input signal
W1Current4mA~20mA DC0mA~10mA DC0mA~20mA DC
W2Voltage1V~5V DC0V~5V DC
W3thermo resistancePt1000.0~400.0棩
W4thermocoupleKTES0.0~999.9棩
12Pressure input signal
Y1Current4mA~20mA DC0mA~10mA DC0mA~20mA DC
Y2Voltage1V~5V DC0V~5V DC
|